{"id":13581,"date":"2021-08-04T09:33:38","date_gmt":"2021-08-04T07:33:38","guid":{"rendered":"https:\/\/www.instrument-solutions.com\/?page_id=13581"},"modified":"2024-11-27T16:37:11","modified_gmt":"2024-11-27T15:37:11","slug":"lc-quick-couplings-optimize","status":"publish","type":"page","link":"https:\/\/www.instrument-solutions.com\/en\/consumables\/lc\/lc-quick-couplings-optimize","title":{"rendered":"LC Quick Couplings Optimize"},"content":{"rendered":"<div  class='flex_column av-7jenas-d127ae31cc7b8e4bab767d2ecbe1099e av_one_full  avia-builder-el-0  el_before_av_one_fourth  avia-builder-el-first  first flex_column_div  '     ><p><section  class='av_textblock_section av-22dwb10-69319ff40cfc8aff817e1781db3e72aa '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><span style=\"color: #606060; font-family: 'Verdana','sans-serif'; font-size: 10pt;\"><a href=\"http:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optimize-Technologies-logo.png\"><img decoding=\"async\" class=\"alignleft wp-image-2471\" src=\"http:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optimize-Technologies-logo.png\" alt=\"Optimize Technologies logo\" width=\"250\" height=\"74\" srcset=\"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optimize-Technologies-logo.png 340w, https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optimize-Technologies-logo-300x88.png 300w\" sizes=\"(max-width: 250px) 100vw, 250px\" \/><\/a><\/span><\/p>\n<p>Optimize is a US manufacturer that develops solutions to make working with the HPLC, UHPLC and LCMS more user-friendly, cost-effective and reliable. The solutions are suitable for the main brands of HPLC systems on the market.<\/p>\n<p>On this page you will find information about the <strong>Optimax<\/strong> Check Valve system and underneath Optilynx Quick Couplings. This allows you to replace columns, guards and filters in no time at all.<\/p>\n<p><span style=\"color: #606060; font-family: 'Verdana','sans-serif'; font-size: 10pt;\">\u00a0<\/span><\/p>\n<\/div><\/section><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-av_heading-92ab2279b656a58398ca1a2235140632\">\n#top .av-special-heading.av-av_heading-92ab2279b656a58398ca1a2235140632{\npadding-bottom:10px;\n}\nbody .av-special-heading.av-av_heading-92ab2279b656a58398ca1a2235140632 .av-special-heading-tag .heading-char{\nfont-size:25px;\n}\n.av-special-heading.av-av_heading-92ab2279b656a58398ca1a2235140632 .av-subheading{\nfont-size:15px;\n}\n<\/style>\n<div  class='av-special-heading av-av_heading-92ab2279b656a58398ca1a2235140632 av-special-heading-h2  avia-builder-el-2  el_after_av_textblock  el_before_av_textblock '><h2 class='av-special-heading-tag '  itemprop=\"headline\"  >Optimax Check Valve System<\/h2><div class=\"special-heading-border\"><div class=\"special-heading-inner-border\"><\/div><\/div><\/div><br \/>\n<section  class='av_textblock_section av-1xz2pp0-635a4d4259e4300bcd257a66be649e87 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p>Check valves are a crucial component of the HPLC. A well-functioning check valve goes almost unnoticed, while a malfunctioning one can lead to baseline noise, pressure fluctuations and inconsistent flow.<\/p>\n<p>With the Optimax check valve system you can <strong>replace check valves faster<\/strong>, <strong>cheaper<\/strong> and <strong>easier<\/strong> than ever before. Increase the uptime of your HPLC system with less risk of leakage.<\/p>\n<p><a href=\"http:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optimax-check-valves-overview.png\"><br \/>\n<img decoding=\"async\" class=\"alignright wp-image-2470\" src=\"http:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optimax-check-valves-overview.png\" alt=\"Optimax check valves overview\" width=\"300\" height=\"124\" srcset=\"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optimax-check-valves-overview.png 599w, https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optimax-check-valves-overview-300x124.png 300w, https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optimax-check-valves-overview-450x186.png 450w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>The Opti-Max\u00ae Free-Turn\u00ae housing can be removed while the tubing remains connected. Check valve maintenance is thus faster and wear and tear of the fitting is reduced.<\/p>\n<p>One type of cartridge works in both the inlet and outlet positions. Suitable for all HPLC systems. It is very simple:<\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<\/div><\/section><\/p><\/div>\n<div  class='flex_column av-6sz01g-098831c9172df9b98def527a1e1ad27b av_one_fourth  avia-builder-el-4  el_after_av_one_full  el_before_av_one_fourth  first flex_column_div  column-top-margin'     ><style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-1v16zh0-931fde214f03717d3f61ce6360ef68a2\">\n.avia-image-container.av-1v16zh0-931fde214f03717d3f61ce6360ef68a2 img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-1v16zh0-931fde214f03717d3f61ce6360ef68a2 .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-1v16zh0-931fde214f03717d3f61ce6360ef68a2 av-styling- avia-align-center  avia-builder-el-5  avia-builder-el-no-sibling '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img fetchpriority=\"high\" decoding=\"async\" fetchpriority=\"high\" fetchpriority=\"high\" class='wp-image-9327 avia-img-lazy-loading-not-9327 avia_image ' src=\"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optimax-Turn-1-van-4.png\" alt='' title='Optimax Turn 1 van 4'  height=\"216\" width=\"263\"  itemprop=\"thumbnailUrl\"  \/><\/div><\/div><\/div><\/div>\n<div  class='flex_column av-6i8cac-7812df91d7e246ba11293b029f060591 av_one_fourth  avia-builder-el-6  el_after_av_one_fourth  el_before_av_one_fourth  flex_column_div  column-top-margin'     ><style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-1s97nus-6fd7cbee51bbeb6c73e771627b1a23bc\">\n.avia-image-container.av-1s97nus-6fd7cbee51bbeb6c73e771627b1a23bc img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-1s97nus-6fd7cbee51bbeb6c73e771627b1a23bc .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-1s97nus-6fd7cbee51bbeb6c73e771627b1a23bc av-styling- avia-align-center  avia-builder-el-7  avia-builder-el-no-sibling '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img fetchpriority=\"high\" decoding=\"async\" fetchpriority=\"high\" fetchpriority=\"high\" class='wp-image-9328 avia-img-lazy-loading-not-9328 avia_image ' src=\"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optimax-Turn-2-van-4.png\" alt='' title='Optimax Turn 2 van 4'  height=\"216\" width=\"264\"  itemprop=\"thumbnailUrl\"  \/><\/div><\/div><\/div><\/div>\n<div  class='flex_column av-1qbivhw-dc0ca78ebb33a83feaacdeefd3e2b825 av_one_fourth  avia-builder-el-8  el_after_av_one_fourth  el_before_av_one_fourth  flex_column_div  column-top-margin'     ><style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-1omg0jo-35661e017c48fdd0c8868fea77c5caf5\">\n.avia-image-container.av-1omg0jo-35661e017c48fdd0c8868fea77c5caf5 img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-1omg0jo-35661e017c48fdd0c8868fea77c5caf5 .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-1omg0jo-35661e017c48fdd0c8868fea77c5caf5 av-styling- avia-align-center  avia-builder-el-9  avia-builder-el-no-sibling '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img fetchpriority=\"high\" decoding=\"async\" fetchpriority=\"high\" fetchpriority=\"high\" class='wp-image-9329 avia-img-lazy-loading-not-9329 avia_image ' src=\"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optimax-Turn-3-van-4.png\" alt='' title='Optimax Turn 3 van 4'  height=\"221\" width=\"265\"  itemprop=\"thumbnailUrl\"  \/><\/div><\/div><\/div><\/div>\n<div  class='flex_column av-1mxry04-9e512f856bc4f33409ea33ab346592bb av_one_fourth  avia-builder-el-10  el_after_av_one_fourth  el_before_av_hr  flex_column_div  column-top-margin'     ><style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-5qa95g-5545ee36571b65654caa834743e9647f\">\n.avia-image-container.av-5qa95g-5545ee36571b65654caa834743e9647f img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-5qa95g-5545ee36571b65654caa834743e9647f .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-5qa95g-5545ee36571b65654caa834743e9647f av-styling- avia-align-center  avia-builder-el-11  avia-builder-el-no-sibling '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img fetchpriority=\"high\" decoding=\"async\" fetchpriority=\"high\" fetchpriority=\"high\" class='wp-image-9330 avia-img-lazy-loading-not-9330 avia_image ' src=\"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optimax-Turn-4-van-4.png\" alt='' title='Optimax Turn 4 van 4'  height=\"219\" width=\"264\"  itemprop=\"thumbnailUrl\"  \/><\/div><\/div><\/div><\/div>\n<div  class='hr av-1j67yzo-d8ba9d58625c8a94b7164c12d16def21 hr-default  avia-builder-el-12  el_after_av_one_fourth  el_before_av_one_fourth '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div>\n<div  class='flex_column av-5cri04-495a104203459ff47ed546611ce07530 av_one_fourth  avia-builder-el-13  el_after_av_hr  el_before_av_one_fourth  first flex_column_div  '     ><section  class='av_textblock_section av-1g9o95w-ad5c1c46a42f9325104816daa1d05487 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><strong>Cost savings<\/strong><\/p>\n<p>A single cartridge operates in both inlet and outlet positions. And that for most brands of HPLCs on the market. With some cartridges in stock, you are well prepared to replace check valves if necessary. The service life of the tubes, fittings and the seal of the check valve is considerably extended because they are not loaded when replacing check valves.<\/p>\n<\/div><\/section><\/div>\n<div  class='flex_column av-4zm8ys-b526d482ebc4996f96f471485b5188f2 av_one_fourth  avia-builder-el-15  el_after_av_one_fourth  el_before_av_one_fourth  flex_column_div  '     ><section  class='av_textblock_section av-1dj288k-7424a9e5e728387232eca3d50404e615 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><strong>Performance<\/strong><\/p>\n<p>Optimize makes check valves as responsive as possible. Each set of ball and seat is individually tuned to ensure a lock-and-key fit. In the nitrogen bubble test, the industry standard test, 12 air bubbles per minute is generally acceptable. Optimax, however, scores 3 bubbles per minute.<\/p>\n<\/div><\/section><\/div>\n<div  class='flex_column av-1azj9es-208d0da5bff05864d002a0f04fabeedb av_one_fourth  avia-builder-el-17  el_after_av_one_fourth  el_before_av_one_fourth  flex_column_div  '     ><section  class='av_textblock_section av-1a2qhp0-37ac4810fa9aa3204d8e9fc131431741 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><strong>Sustainability<\/strong><\/p>\n<p>The end caps of the check valves are made of PEEK. This ensures a maximum service life and a seal that can withstand high pressure and the effects of temperature changes. Therefore, no additional seals are required for installation, which significantly reduces the risk of leakage.<\/p>\n<\/div><\/section><\/div>\n<div  class='flex_column av-17js3lw-72f69fd3b9b72cf70b7af7ccacfa78e0 av_one_fourth  avia-builder-el-19  el_after_av_one_fourth  el_before_av_button  flex_column_div  '     ><section  class='av_textblock_section av-15urt90-72eeacce86c1cbb63177a4d2baf8063a '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><strong>Material<\/strong><\/p>\n<p>For large mechanical forces, stainless steel cartridges are the best choice. Ceramic ball &#038; seat sets have a higher density which makes the valve more responsive and makes the ball\/seat faster in light solvents. Use PEEK cartridges with ceramic balls &#038; Seats for HPLC systems with nonmetallic flow path that are biocompatible or contain high levels of THF.<\/p>\n<p>Both mentioned cartridge materials are also available with ball &#038; seat combinations of ruby and sapphire.<\/p>\n<\/div><\/section><\/div>\n<div  class='avia-button-wrap av-14jspmc-18b2021d1ba5574d1dcb5358d25f0b97-wrap avia-button-left  avia-builder-el-21  el_after_av_one_fourth  el_before_av_hr '><a href='\/wp-content\/uploads\/Optimize-Technologies-catalogus-2010.pdf'  class='avia-button av-14jspmc-18b2021d1ba5574d1dcb5358d25f0b97 av-link-btn avia-icon_select-yes-left-icon avia-size-small avia-position-left avia-color-theme-color'  target=\"_blank\"  rel=\"noopener noreferrer\"  aria-label=\"download catalog Optimize Technologies\"><span class='avia_button_icon avia_button_icon_left avia-iconfont avia-font-entypo-fontello' data-av_icon='\ue82d' data-av_iconfont='entypo-fontello' ><\/span><span class='avia_iconbox_title' >download catalog Optimize Technologies<\/span><\/a><\/div>\n<div  class='hr av-13bkf38-9e2da489ea4bb40a4fcc1aa82018bf84 hr-default  avia-builder-el-22  el_after_av_button  el_before_av_one_full '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div>\n<div  class='flex_column av-11x1cz8-fe931d86ad140da2650fc6412c47f729 av_one_full  avia-builder-el-23  el_after_av_hr  el_before_av_one_fourth  first flex_column_div  '     ><p>\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-jze4hrfi-effd0bc106d9dc903e010e6144c3e70b\">\n#top .av-special-heading.av-jze4hrfi-effd0bc106d9dc903e010e6144c3e70b{\npadding-bottom:10px;\n}\nbody .av-special-heading.av-jze4hrfi-effd0bc106d9dc903e010e6144c3e70b .av-special-heading-tag .heading-char{\nfont-size:25px;\n}\n.av-special-heading.av-jze4hrfi-effd0bc106d9dc903e010e6144c3e70b .av-subheading{\nfont-size:15px;\n}\n<\/style>\n<div  class='av-special-heading av-jze4hrfi-effd0bc106d9dc903e010e6144c3e70b av-special-heading-h2  avia-builder-el-24  el_before_av_textblock  avia-builder-el-first '><h2 class='av-special-heading-tag '  itemprop=\"headline\"  >Optilynx Shortcuts<\/h2><div class=\"special-heading-border\"><div class=\"special-heading-inner-border\"><\/div><\/div><\/div><br \/>\n<section  class='av_textblock_section av-y2ekro-9734b614d529aefa7fd4e7a8aadfa958 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p>With Optilynx shortcuts you can replace columns, Guards, stair columns, in-line and front-column filters in literally no time at all.<\/p>\n<p>Operation in 4 steps:<\/p>\n<\/div><\/section><\/p><\/div>\n<div  class='flex_column av-vms7o4-0f1bc2f8194142123ee32a607b996c24 av_one_fourth  avia-builder-el-26  el_after_av_one_full  el_before_av_one_fourth  first flex_column_div  column-top-margin'     ><style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-uhhsv8-e78ca4af7d186bbf269d9ddc7ad062cc\">\n.avia-image-container.av-uhhsv8-e78ca4af7d186bbf269d9ddc7ad062cc img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-uhhsv8-e78ca4af7d186bbf269d9ddc7ad062cc .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-uhhsv8-e78ca4af7d186bbf269d9ddc7ad062cc av-styling- avia-align-center  avia-builder-el-27  avia-builder-el-no-sibling '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img fetchpriority=\"high\" decoding=\"async\" fetchpriority=\"high\" fetchpriority=\"high\" class='wp-image-9319 avia-img-lazy-loading-not-9319 avia_image ' src=\"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optilynx-how-it-works-1.png\" alt='' title='Optilynx how it works 1'  height=\"211\" width=\"211\"  itemprop=\"thumbnailUrl\" srcset=\"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optilynx-how-it-works-1.png 211w, https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optilynx-how-it-works-1-150x150.png 150w, https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optilynx-how-it-works-1-36x36.png 36w, https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optilynx-how-it-works-1-180x180.png 180w, https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optilynx-how-it-works-1-120x120.png 120w\" sizes=\"(max-width: 211px) 100vw, 211px\" \/><\/div><\/div><\/div><\/div>\n<div  class='flex_column av-sfdjro-69f547d6802f052fdf0035bc306ceab1 av_one_fourth  avia-builder-el-28  el_after_av_one_fourth  el_before_av_one_fourth  flex_column_div  column-top-margin'     ><style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-qqq4dg-402607ce39363cf07a5b6e52b1e1d795\">\n.avia-image-container.av-qqq4dg-402607ce39363cf07a5b6e52b1e1d795 img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-qqq4dg-402607ce39363cf07a5b6e52b1e1d795 .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-qqq4dg-402607ce39363cf07a5b6e52b1e1d795 av-styling- avia-align-center  avia-builder-el-29  avia-builder-el-no-sibling '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img fetchpriority=\"high\" decoding=\"async\" fetchpriority=\"high\" fetchpriority=\"high\" class='wp-image-9320 avia-img-lazy-loading-not-9320 avia_image ' src=\"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optilynx-how-it-works-2.png\" alt='' title='Optilynx how it works 2'  height=\"210\" width=\"209\"  itemprop=\"thumbnailUrl\" srcset=\"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optilynx-how-it-works-2.png 209w, https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optilynx-how-it-works-2-150x150.png 150w, https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optilynx-how-it-works-2-36x36.png 36w, https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optilynx-how-it-works-2-180x180.png 180w, https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optilynx-how-it-works-2-120x120.png 120w\" sizes=\"(max-width: 209px) 100vw, 209px\" \/><\/div><\/div><\/div><\/div>\n<div  class='flex_column av-q5ivis-fb29a696d6adc69ebd58b39e8338f464 av_one_fourth  avia-builder-el-30  el_after_av_one_fourth  el_before_av_one_fourth  flex_column_div  column-top-margin'     ><style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-8k75g-47fc4d0e5b8edad4c3bcda365c685e0c\">\n.avia-image-container.av-8k75g-47fc4d0e5b8edad4c3bcda365c685e0c img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-8k75g-47fc4d0e5b8edad4c3bcda365c685e0c .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-8k75g-47fc4d0e5b8edad4c3bcda365c685e0c av-styling- avia-align-center  avia-builder-el-31  avia-builder-el-no-sibling '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img fetchpriority=\"high\" decoding=\"async\" fetchpriority=\"high\" fetchpriority=\"high\" class='wp-image-9321 avia-img-lazy-loading-not-9321 avia_image ' src=\"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optilynx-how-it-works-3.png\" alt='' title='Optilynx how it works 3'  height=\"210\" width=\"347\"  itemprop=\"thumbnailUrl\" srcset=\"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optilynx-how-it-works-3.png 347w, https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optilynx-how-it-works-3-300x182.png 300w\" sizes=\"(max-width: 347px) 100vw, 347px\" \/><\/div><\/div><\/div><\/div>\n<div  class='flex_column av-mzk2wk-23c59b4e2d91acae7535791b4ce4161a av_one_fourth  avia-builder-el-32  el_after_av_one_fourth  el_before_av_one_full  flex_column_div  column-top-margin'     ><style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-kektd0-5ecdba73600609c6fc715d03cd71d919\">\n.avia-image-container.av-kektd0-5ecdba73600609c6fc715d03cd71d919 img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-kektd0-5ecdba73600609c6fc715d03cd71d919 .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-kektd0-5ecdba73600609c6fc715d03cd71d919 av-styling- avia-align-center  avia-builder-el-33  avia-builder-el-no-sibling '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img fetchpriority=\"high\" decoding=\"async\" fetchpriority=\"high\" fetchpriority=\"high\" class='wp-image-9322 avia-img-lazy-loading-not-9322 avia_image ' src=\"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optilynx-how-it-works-4.png\" alt='' title='Optilynx how it works 4'  height=\"211\" width=\"290\"  itemprop=\"thumbnailUrl\"  \/><\/div><\/div><\/div><\/div>\n<div  class='flex_column av-1xg76s-49ad5ab0942ecbf848491adf1f625e6d av_one_full  avia-builder-el-34  el_after_av_one_fourth  el_before_av_one_third  first flex_column_div  column-top-margin'     ><section  class='av_textblock_section av-hiztj8-b632d701770cc6f413fd057703919284 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><strong><a href=\"http:\/\/www.instrument-solutions.com\/wp-content\/uploads\/OptiLynx-quick-connect.png\"><img decoding=\"async\" class=\"alignright wp-image-2468\" src=\"http:\/\/www.instrument-solutions.com\/wp-content\/uploads\/OptiLynx-quick-connect.png\" alt=\"OptiLynx quick connect\" width=\"84\" height=\"400\" srcset=\"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/OptiLynx-quick-connect.png 137w, https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/OptiLynx-quick-connect-63x300.png 63w\" sizes=\"(max-width: 84px) 100vw, 84px\" \/><\/a><\/strong><\/p>\n<p><strong>Literally change columns in a jiffy.<\/strong><br \/>\nThe OptiLynx Quick-Connect system improves the uptime of your HPLC. You can quickly and easily replace analytical HPLC columns <strong>without<\/strong> the need for<strong> tools<\/strong>. The tubing remains attached, so that the risk of leakage is also greatly reduced.<br \/>\nIn no time at all, you can also replace other consumables that occur in the flow system, such as Guard and Stair columns, in-line and front column filters.<br \/>\nThe system is based on the bayonet connection. A convenient, secure and fast way to make or disconnect a connection, without the use of tools.<\/p>\n<p><strong>Advantages<\/strong><\/p>\n<ul>\n<li>Tubing does not need to be disconnected, which significantly reduces the risk of leakage.<\/li>\n<li>Quartz turn connection, suitable for up to 6000 psi<\/li>\n<li>low volume\/low dispersion interface for volume critical applications<\/li>\n<li>True Zero-Dead volume connection<\/li>\n<li>no tools required<\/li>\n<\/ul>\n<p><strong>\u00a0<\/strong><\/p>\n<\/div><\/section><\/div>\n<div  class='flex_column av-gi4vh0-794e4e94d87db755754d8ee81a79fc6f av_one_third  avia-builder-el-36  el_after_av_one_full  el_before_av_one_third  first flex_column_div  column-top-margin'     ><section  class='av_textblock_section av-dtrfs4-b5250c5956a594c300e8ce1c43b3851f '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><strong>Exchange column<\/strong><\/p>\n<p>By attaching the Opti-Lynx universal door adapters to the columns, they can be changed quickly. This simple column switch is easy to install and there is no need to purchase expensive high-pressure valves.<\/p>\n<\/div><\/section><\/div>\n<div  class='flex_column av-btpk5g-35ad9f62a50f51395eebbbba3c4bfbb3 av_one_third  avia-builder-el-38  el_after_av_one_third  el_before_av_one_third  flex_column_div  column-top-margin'     ><section  class='av_textblock_section av-a5d9zo-3d67bb17e44be21799b48cc4d0676605 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><strong>Changing from Guard column to filter<\/strong><br \/>\nFor one method you need a filter and for the other method you need a Guard column. no problem. Choose the right insert, connect it with the right pipe holder and you can continue working. The only tools you need are your fingers.<\/p>\n<\/div><\/section><\/div>\n<div  class='flex_column av-9kvjck-e00ee68898eebb1f2da73f208d6c84c7 av_one_third  avia-builder-el-40  el_after_av_one_third  el_before_av_one_full  flex_column_div  column-top-margin'     ><section  class='av_textblock_section av-6wko90-263452bc979367e81eb00d344dc7188f '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><strong>Switching the flowpad<\/strong><\/p>\n<p>If you want to divert the flow path efficiently, the Opti-Lynx In-Line Kit is your solution. Connect one line with a Cap Holder and create extra bayonet connector for each matching tube connection. Changing the flowpad becomes an easy task.<\/p>\n<\/div><\/section><\/div>\n<div  class='flex_column av-iwa7o-f4c388aaebf084b45d21c01dadcffc91 av_one_full  avia-builder-el-42  el_after_av_one_third  avia-builder-el-last  first flex_column_div  column-top-margin'     ><p>\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-jze4n62q-5ea8a833166b42abd9b69af30c89e11b\">\n#top .av-special-heading.av-jze4n62q-5ea8a833166b42abd9b69af30c89e11b{\npadding-bottom:10px;\n}\nbody .av-special-heading.av-jze4n62q-5ea8a833166b42abd9b69af30c89e11b .av-special-heading-tag .heading-char{\nfont-size:25px;\n}\n.av-special-heading.av-jze4n62q-5ea8a833166b42abd9b69af30c89e11b .av-subheading{\nfont-size:15px;\n}\n<\/style>\n<div  class='av-special-heading av-jze4n62q-5ea8a833166b42abd9b69af30c89e11b av-special-heading-h2  avia-builder-el-43  el_before_av_codeblock  avia-builder-el-first '><h2 class='av-special-heading-tag '  itemprop=\"headline\"  >Contact Form<\/h2><div class=\"special-heading-border\"><div class=\"special-heading-inner-border\"><\/div><\/div><\/div><br \/>\n<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":13520,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-13581","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>LC Quick Couplings Optimize - Instrument Solutions Benelux<\/title>\n<meta name=\"description\" content=\"lc hplc quick couplings optimize. Handy, quick and easy to change your lc, hplc columns and check valves\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.instrument-solutions.com\/en\/consumables\/lc\/lc-quick-couplings-optimize\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"LC Quick Couplings Optimize - Instrument Solutions Benelux\" \/>\n<meta property=\"og:description\" content=\"lc hplc quick couplings optimize. Handy, quick and easy to change your lc, hplc columns and check valves\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.instrument-solutions.com\/en\/consumables\/lc\/lc-quick-couplings-optimize\" \/>\n<meta property=\"og:site_name\" content=\"Instrument Solutions\" \/>\n<meta property=\"article:modified_time\" content=\"2024-11-27T15:37:11+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optimize-Technologies-logo.png\" \/>\n\t<meta property=\"og:image:width\" content=\"340\" \/>\n\t<meta property=\"og:image:height\" content=\"100\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\\\/lc\\\/lc-quick-couplings-optimize\",\"url\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\\\/lc\\\/lc-quick-couplings-optimize\",\"name\":\"LC Quick Couplings Optimize - Instrument Solutions Benelux\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\\\/lc\\\/lc-quick-couplings-optimize#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\\\/lc\\\/lc-quick-couplings-optimize#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/www.instrument-solutions.com\\\/wp-content\\\/uploads\\\/Optimize-Technologies-logo.png\",\"datePublished\":\"2021-08-04T07:33:38+00:00\",\"dateModified\":\"2024-11-27T15:37:11+00:00\",\"description\":\"lc hplc quick couplings optimize. Handy, quick and easy to change your lc, hplc columns and check valves\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\\\/lc\\\/lc-quick-couplings-optimize#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\\\/lc\\\/lc-quick-couplings-optimize\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\\\/lc\\\/lc-quick-couplings-optimize#primaryimage\",\"url\":\"http:\\\/\\\/www.instrument-solutions.com\\\/wp-content\\\/uploads\\\/Optimize-Technologies-logo.png\",\"contentUrl\":\"http:\\\/\\\/www.instrument-solutions.com\\\/wp-content\\\/uploads\\\/Optimize-Technologies-logo.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\\\/lc\\\/lc-quick-couplings-optimize#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/home\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Consumables\",\"item\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Consumables LC\",\"item\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\\\/lc\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"LC Quick Couplings Optimize\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en#website\",\"url\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\",\"name\":\"Instrument Solutions\",\"description\":\"elementanalyse | chromatografie | elektronische sensing\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en#organization\",\"name\":\"Instrument Solutions Benelux B.V.\",\"url\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.instrument-solutions.com\\\/wp-content\\\/uploads\\\/logo-instrument-solutions-transparant.png\",\"contentUrl\":\"https:\\\/\\\/www.instrument-solutions.com\\\/wp-content\\\/uploads\\\/logo-instrument-solutions-transparant.png\",\"width\":728,\"height\":325,\"caption\":\"Instrument Solutions Benelux B.V.\"},\"image\":{\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"LC Quick Couplings Optimize - Instrument Solutions Benelux","description":"lc hplc quick couplings optimize. Handy, quick and easy to change your lc, hplc columns and check valves","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.instrument-solutions.com\/en\/consumables\/lc\/lc-quick-couplings-optimize","og_locale":"en_US","og_type":"article","og_title":"LC Quick Couplings Optimize - Instrument Solutions Benelux","og_description":"lc hplc quick couplings optimize. Handy, quick and easy to change your lc, hplc columns and check valves","og_url":"https:\/\/www.instrument-solutions.com\/en\/consumables\/lc\/lc-quick-couplings-optimize","og_site_name":"Instrument Solutions","article_modified_time":"2024-11-27T15:37:11+00:00","og_image":[{"width":340,"height":100,"url":"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optimize-Technologies-logo.png","type":"image\/png"}],"twitter_misc":{"Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.instrument-solutions.com\/en\/consumables\/lc\/lc-quick-couplings-optimize","url":"https:\/\/www.instrument-solutions.com\/en\/consumables\/lc\/lc-quick-couplings-optimize","name":"LC Quick Couplings Optimize - Instrument Solutions Benelux","isPartOf":{"@id":"https:\/\/www.instrument-solutions.com\/en#website"},"primaryImageOfPage":{"@id":"https:\/\/www.instrument-solutions.com\/en\/consumables\/lc\/lc-quick-couplings-optimize#primaryimage"},"image":{"@id":"https:\/\/www.instrument-solutions.com\/en\/consumables\/lc\/lc-quick-couplings-optimize#primaryimage"},"thumbnailUrl":"http:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optimize-Technologies-logo.png","datePublished":"2021-08-04T07:33:38+00:00","dateModified":"2024-11-27T15:37:11+00:00","description":"lc hplc quick couplings optimize. Handy, quick and easy to change your lc, hplc columns and check valves","breadcrumb":{"@id":"https:\/\/www.instrument-solutions.com\/en\/consumables\/lc\/lc-quick-couplings-optimize#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.instrument-solutions.com\/en\/consumables\/lc\/lc-quick-couplings-optimize"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.instrument-solutions.com\/en\/consumables\/lc\/lc-quick-couplings-optimize#primaryimage","url":"http:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optimize-Technologies-logo.png","contentUrl":"http:\/\/www.instrument-solutions.com\/wp-content\/uploads\/Optimize-Technologies-logo.png"},{"@type":"BreadcrumbList","@id":"https:\/\/www.instrument-solutions.com\/en\/consumables\/lc\/lc-quick-couplings-optimize#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.instrument-solutions.com\/en\/home"},{"@type":"ListItem","position":2,"name":"Consumables","item":"https:\/\/www.instrument-solutions.com\/en\/consumables"},{"@type":"ListItem","position":3,"name":"Consumables LC","item":"https:\/\/www.instrument-solutions.com\/en\/consumables\/lc"},{"@type":"ListItem","position":4,"name":"LC Quick Couplings Optimize"}]},{"@type":"WebSite","@id":"https:\/\/www.instrument-solutions.com\/en#website","url":"https:\/\/www.instrument-solutions.com\/en","name":"Instrument Solutions","description":"elementanalyse | chromatografie | elektronische sensing","publisher":{"@id":"https:\/\/www.instrument-solutions.com\/en#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.instrument-solutions.com\/en?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.instrument-solutions.com\/en#organization","name":"Instrument Solutions Benelux B.V.","url":"https:\/\/www.instrument-solutions.com\/en","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.instrument-solutions.com\/en#\/schema\/logo\/image\/","url":"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/logo-instrument-solutions-transparant.png","contentUrl":"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/logo-instrument-solutions-transparant.png","width":728,"height":325,"caption":"Instrument Solutions Benelux B.V."},"image":{"@id":"https:\/\/www.instrument-solutions.com\/en#\/schema\/logo\/image\/"}}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/www.instrument-solutions.com\/en\/wp-json\/wp\/v2\/pages\/13581","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.instrument-solutions.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.instrument-solutions.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.instrument-solutions.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.instrument-solutions.com\/en\/wp-json\/wp\/v2\/comments?post=13581"}],"version-history":[{"count":3,"href":"https:\/\/www.instrument-solutions.com\/en\/wp-json\/wp\/v2\/pages\/13581\/revisions"}],"predecessor-version":[{"id":25153,"href":"https:\/\/www.instrument-solutions.com\/en\/wp-json\/wp\/v2\/pages\/13581\/revisions\/25153"}],"up":[{"embeddable":true,"href":"https:\/\/www.instrument-solutions.com\/en\/wp-json\/wp\/v2\/pages\/13520"}],"wp:attachment":[{"href":"https:\/\/www.instrument-solutions.com\/en\/wp-json\/wp\/v2\/media?parent=13581"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}