{"id":13460,"date":"2021-08-03T12:14:22","date_gmt":"2021-08-03T10:14:22","guid":{"rendered":"https:\/\/www.instrument-solutions.com\/?page_id=13460"},"modified":"2025-10-30T15:42:06","modified_gmt":"2025-10-30T14:42:06","slug":"gc-filters","status":"publish","type":"page","link":"https:\/\/www.instrument-solutions.com\/en\/consumables\/gc\/gc-filters","title":{"rendered":"GC Filters"},"content":{"rendered":"<div  class='flex_column av-12qdlkh-7612aeb91c85457911c6bfe13b369376 av_two_third  avia-builder-el-0  el_before_av_one_third  avia-builder-el-first  first flex_column_div  '     ><p>\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-av_heading-c9fd0a25ae6c53a99a0d384917384bf3\">\n#top .av-special-heading.av-av_heading-c9fd0a25ae6c53a99a0d384917384bf3{\npadding-bottom:10px;\n}\nbody .av-special-heading.av-av_heading-c9fd0a25ae6c53a99a0d384917384bf3 .av-special-heading-tag .heading-char{\nfont-size:25px;\n}\n.av-special-heading.av-av_heading-c9fd0a25ae6c53a99a0d384917384bf3 .av-subheading{\nfont-size:15px;\n}\n<\/style>\n<div  class='av-special-heading av-av_heading-c9fd0a25ae6c53a99a0d384917384bf3 av-special-heading-h2  avia-builder-el-1  el_before_av_textblock  avia-builder-el-first '><h2 class='av-special-heading-tag '  itemprop=\"headline\"  >GC filters<\/h2><div class=\"special-heading-border\"><div class=\"special-heading-inner-border\"><\/div><\/div><\/div><br \/>\n<section  class='av_textblock_section av-zxsewx-83babf9bdaec9dd95f99e8ce50d93a67 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><a href=\"http:\/\/www.instrument-solutions.com\/wp-content\/uploads\/SGT-logo.jpg\"><img decoding=\"async\" class=\"alignleft wp-image-1950\" src=\"http:\/\/www.instrument-solutions.com\/wp-content\/uploads\/SGT-logo-300x103.jpg\" alt=\"SGT logo\" width=\"150\" height=\"52\" srcset=\"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/SGT-logo-300x103.jpg 300w, https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/SGT-logo.jpg 337w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/a><\/p>\n<p><strong>Gas filtering system Super Clean\u2122<\/strong><\/p>\n<p>Is a cartridge system from SGT Scientific Glass Technology that makes changing GC gas filters quick and easy. The base plate of the filter cartridge is equipped with a non-return valve that ensures that no oxygen enters the cartridge when a filter is changed. Your system will therefore not be contaminated.<\/p>\n<p><strong>Why is gas purity important?<\/strong><\/p>\n<p>Depending on the configuration of the gas chromatograph, you will need one or more gases. Pollutants in the gases can cause ghost peaks in the chromatogram, making your analytical data less valid. The carrier gas must contain less than 1 ppm of oxygen, moisture or other trace contaminants to prevent degradation of GC columns, to extend the life of GC columns and to reduce bleeding of the stationary phase. But detector gases also need to be clean to measure components at low concentrations. For example, hydrogen, air and make-up gas from an FID detector must be free of contaminants to avoid fluctuations and excessive baseline noise.<\/p>\n<p>Gas scrubber filters placed close to the gas chromatograph prevent many problems, extend the life of columns, reduce maintenance on the GC and provide more reliable data.\u00a0Especially when using 5.0 or 6.0 quality gases.<\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<\/div><\/section><br \/>\n<div  class='avia-button-wrap av-xujnhd-b4823117f9003e85cea450bcde481fa4-wrap avia-button-left  avia-builder-el-3  el_after_av_textblock  avia-builder-el-last '><a href='https:\/\/www.instrument-solutions.com\/en\/support\/customer-service\/price-inquiry'  class='avia-button av-xujnhd-b4823117f9003e85cea450bcde481fa4 av-link-btn avia-icon_select-yes-left-icon avia-size-medium avia-position-left avia-color-theme-color'  target=\"_blank\"  rel=\"noopener noreferrer\"  aria-label=\"Quotation request\"><span class='avia_button_icon avia_button_icon_left avia-svg-icon avia-font-svg_entypo-fontello' data-av_svg_icon='book-open' data-av_iconset='svg_entypo-fontello'><svg version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"29\" height=\"32\" viewBox=\"0 0 29 32\" preserveAspectRatio=\"xMidYMid meet\" aria-labelledby='av-svg-title-1' aria-describedby='av-svg-desc-1' role=\"graphics-symbol\">\n<title id='av-svg-title-1'>Book-open<\/title>\n<desc id='av-svg-desc-1'>Book-open<\/desc>\n<path d=\"M10.88 19.584v2.176l-6.4-2.56v-2.176zM10.88 12.928v2.176l-6.4-2.56v-2.176zM28.096 1.856q0.704 0.384 0.704 1.344v20.48q0 1.088-1.024 1.472l-12.736 5.12q-0.256 0.064-0.32 0.064t-0.16 0.032-0.16 0.032-0.16-0.032-0.16-0.032l-0.32-0.064-12.736-5.12q-1.024-0.384-1.024-1.472v-20.48q0-0.96 0.704-1.344 0.704-0.512 1.472-0.192l12.224 4.928 12.224-4.928q0.768-0.32 1.472 0.192zM12.8 27.072v-17.92l-10.24-4.096v17.92zM26.24 22.976v-17.92l-10.24 4.096v17.92zM24.32 17.024v2.176l-6.4 2.56v-2.176zM24.32 10.368v2.176l-6.4 2.56v-2.176z\"><\/path>\n<\/svg><\/span><span class='avia_iconbox_title' >Quotation request<\/span><\/a><\/div><\/p><\/div>\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-wu4cox-f2d88ab094c77af22b84028f7d77ecbe\">\n.flex_column.av-wu4cox-f2d88ab094c77af22b84028f7d77ecbe{\nborder-radius:0px 0px 0px 0px;\npadding:0px 0px 0px 0px;\n}\n<\/style>\n<div  class='flex_column av-wu4cox-f2d88ab094c77af22b84028f7d77ecbe av_one_third  avia-builder-el-4  el_after_av_two_third  el_before_av_hr  flex_column_div av-zero-column-padding  '     ><style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-u6ls41-bffe4b281c2e4697a6ab3cd750369531\">\n.avia-image-container.av-u6ls41-bffe4b281c2e4697a6ab3cd750369531 img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-u6ls41-bffe4b281c2e4697a6ab3cd750369531 .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-u6ls41-bffe4b281c2e4697a6ab3cd750369531 av-styling- avia_animated_image av-animated-when-visible-95 pop-up avia-align-center  avia-builder-el-5  avia-builder-el-no-sibling '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img fetchpriority=\"high\" decoding=\"async\" fetchpriority=\"high\" fetchpriority=\"high\" class='wp-image-9199 avia-img-lazy-loading-not-9199 avia_image ' src=\"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/SGT-F0721-e1420715410170.png\" alt='' title='SGT-F0721'  height=\"300\" width=\"55\"  itemprop=\"thumbnailUrl\"  \/><\/div><\/div><\/div><\/div><\/p>\n<div  class='hr av-t5c9cx-63c7058d9ae36fe3815a32766d322a26 hr-default  avia-builder-el-6  el_after_av_one_third  el_before_av_two_third '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div>\n<div  class='flex_column av-rrohsh-2a75d61f1cb48ec49597f09b257a41b7 av_two_third  avia-builder-el-7  el_after_av_hr  el_before_av_one_third  first flex_column_div  '     ><section  class='av_textblock_section av-q0yh7l-1828fb7541e4dea90a528a0a3ec57ca1 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h2>Component gas filtering system<\/h2>\n<p><strong>Baseplate<\/strong><\/p>\n<p>Is the base plate on which the filter is placed with inlet and outlet connections for the gas pipe and two non-return valves that automatically allow the gas flow at the moment the filter is installed.<\/p>\n<p><strong>Universal ring nut<\/strong><\/p>\n<p>This is used to attach the filter cartridge to the base plate. It also serves to confirm the Electronic Maintenance Indicator.<\/p>\n<p><strong>Filter Cartridge<\/strong><\/p>\n<p>The filter cartridge is made of glass to prevent the diffusion of oxygen and is equipped with a plastic housing for safety. The PTFE seals on the bottom of the filler are only punctured when installed on the base plate.<\/p>\n<p><strong>Electronic indicator<\/strong><\/p>\n<p>Warns when filter needs to be replaced or serviced. A saturated filter is a major risk factor for the reliability of the analyses. It can release accumulated contaminants that cause large deviations from the results and therefore unnecessarily shorten the life of the GC column. The use of the indicator is optional.<\/p>\n<\/div><\/section><br \/>\n<div  class='avia-button-wrap av-2d13zl-30ba8de766dffafb2dd7b4971db23abb-wrap avia-button-left  avia-builder-el-9  el_after_av_textblock  el_before_av_button '><a href='\/wp-content\/uploads\/SGT-Super-Clean-gaszuiveringsfilters.pdf'  class='avia-button av-2d13zl-30ba8de766dffafb2dd7b4971db23abb av-link-btn avia-icon_select-yes-left-icon avia-size-small avia-position-left avia-color-theme-color'  target=\"_blank\"  rel=\"noopener noreferrer\"  aria-label=\"download brochure Super Clean gasfilters\"><span class='avia_button_icon avia_button_icon_left avia-iconfont avia-font-entypo-fontello' data-av_icon='\ue82d' data-av_iconfont='entypo-fontello' ><\/span><span class='avia_iconbox_title' >download brochure Super Clean gasfilters<\/span><\/a><\/div><br \/>\n<div  class='avia-button-wrap av-mei6up-004e1dcecf29b80ffd3e4f14be7ad7d1-wrap avia-button-left  avia-builder-el-10  el_after_av_button  avia-builder-el-last '><a href='\/wp-content\/uploads\/SGT-elektronische-indicator-2015.pdf'  class='avia-button av-mei6up-004e1dcecf29b80ffd3e4f14be7ad7d1 av-link-btn avia-icon_select-yes-left-icon avia-size-small avia-position-left avia-color-theme-color'  target=\"_blank\"  rel=\"noopener noreferrer\"  aria-label=\"download brochure elektronische indicator\"><span class='avia_button_icon avia_button_icon_left avia-iconfont avia-font-entypo-fontello' data-av_icon='\ue82d' data-av_iconfont='entypo-fontello' ><\/span><span class='avia_iconbox_title' >download brochure elektronische indicator<\/span><\/a><\/div><\/p><\/div>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-kf013l-35486227ccde1d7aa217c02cc3470574\">\n.flex_column.av-kf013l-35486227ccde1d7aa217c02cc3470574{\nborder-radius:0px 0px 0px 0px;\npadding:0px 0px 0px 0px;\n}\n<\/style>\n<div  class='flex_column av-kf013l-35486227ccde1d7aa217c02cc3470574 av_one_third  avia-builder-el-11  el_after_av_two_third  el_before_av_hr  flex_column_div av-zero-column-padding  '     ><style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-jru9o1-b1f8f1bd678695a687763539035c5036\">\n.avia-image-container.av-jru9o1-b1f8f1bd678695a687763539035c5036 img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-jru9o1-b1f8f1bd678695a687763539035c5036 .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-jru9o1-b1f8f1bd678695a687763539035c5036 av-styling- avia_animated_image av-animated-when-visible-95 pop-up avia-align-center  avia-builder-el-12  avia-builder-el-no-sibling '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img fetchpriority=\"high\" decoding=\"async\" fetchpriority=\"high\" fetchpriority=\"high\" class='wp-image-9202 avia-img-lazy-loading-not-9202 avia_image ' src=\"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/installed_device_new-e1421407730503.png\" alt='' title='SGT filter cartridge'  height=\"200\" width=\"68\"  itemprop=\"thumbnailUrl\"  \/><\/div><\/div><\/div><\/div>\n<div  class='hr av-827arl-5ae4998650764a1cebd41426d6f78a61 hr-default  avia-builder-el-13  el_after_av_one_third  el_before_av_one_full '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div>\n<div  class='flex_column av-6hbbwx-6cf601827d90494578ec9874a5a9ea19 av_one_full  avia-builder-el-14  el_after_av_hr  avia-builder-el-last  first flex_column_div  '     ><p>\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-jzcpfdzy-9ae6354a9920da40ea154770b2354f6c\">\n#top .av-special-heading.av-jzcpfdzy-9ae6354a9920da40ea154770b2354f6c{\npadding-bottom:10px;\n}\nbody .av-special-heading.av-jzcpfdzy-9ae6354a9920da40ea154770b2354f6c .av-special-heading-tag .heading-char{\nfont-size:25px;\n}\n.av-special-heading.av-jzcpfdzy-9ae6354a9920da40ea154770b2354f6c .av-subheading{\nfont-size:15px;\n}\n<\/style>\n<div  class='av-special-heading av-jzcpfdzy-9ae6354a9920da40ea154770b2354f6c av-special-heading-h2  avia-builder-el-15  el_before_av_codeblock  avia-builder-el-first '><h2 class='av-special-heading-tag '  itemprop=\"headline\"  >Contact Form<\/h2><div class=\"special-heading-border\"><div class=\"special-heading-inner-border\"><\/div><\/div><\/div><br \/>\n<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":13900,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-13460","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>GC Filters - Instrument Solutions<\/title>\n<meta name=\"description\" content=\"gas filter, filter for carrier gas GC, GC filters, filters hydrogen H2, filters nitrogen N2, filters helium He, detector filters, gas filters\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.instrument-solutions.com\/en\/consumables\/gc\/gc-filters\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"GC Filters - Instrument Solutions\" \/>\n<meta property=\"og:description\" content=\"gas filter, filter for carrier gas GC, GC filters, filters hydrogen H2, filters nitrogen N2, filters helium He, detector filters, gas filters\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.instrument-solutions.com\/en\/consumables\/gc\/gc-filters\" \/>\n<meta property=\"og:site_name\" content=\"Instrument Solutions\" \/>\n<meta property=\"article:modified_time\" content=\"2025-10-30T14:42:06+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/SGT-logo.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"337\" \/>\n\t<meta property=\"og:image:height\" content=\"116\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\\\/gc\\\/gc-filters\",\"url\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\\\/gc\\\/gc-filters\",\"name\":\"GC Filters - Instrument Solutions\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\\\/gc\\\/gc-filters#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\\\/gc\\\/gc-filters#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/www.instrument-solutions.com\\\/wp-content\\\/uploads\\\/SGT-logo-300x103.jpg\",\"datePublished\":\"2021-08-03T10:14:22+00:00\",\"dateModified\":\"2025-10-30T14:42:06+00:00\",\"description\":\"gas filter, filter for carrier gas GC, GC filters, filters hydrogen H2, filters nitrogen N2, filters helium He, detector filters, gas filters\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\\\/gc\\\/gc-filters#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\\\/gc\\\/gc-filters\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\\\/gc\\\/gc-filters#primaryimage\",\"url\":\"http:\\\/\\\/www.instrument-solutions.com\\\/wp-content\\\/uploads\\\/SGT-logo-300x103.jpg\",\"contentUrl\":\"http:\\\/\\\/www.instrument-solutions.com\\\/wp-content\\\/uploads\\\/SGT-logo-300x103.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\\\/gc\\\/gc-filters#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/home\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Consumables\",\"item\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Consumables GC\",\"item\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\\\/consumables\\\/gc\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"GC Filters\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en#website\",\"url\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\",\"name\":\"Instrument Solutions\",\"description\":\"elementanalyse | chromatografie | elektronische sensing\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en#organization\",\"name\":\"Instrument Solutions Benelux B.V.\",\"url\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.instrument-solutions.com\\\/wp-content\\\/uploads\\\/logo-instrument-solutions-transparant.png\",\"contentUrl\":\"https:\\\/\\\/www.instrument-solutions.com\\\/wp-content\\\/uploads\\\/logo-instrument-solutions-transparant.png\",\"width\":728,\"height\":325,\"caption\":\"Instrument Solutions Benelux B.V.\"},\"image\":{\"@id\":\"https:\\\/\\\/www.instrument-solutions.com\\\/en#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"GC Filters - Instrument Solutions","description":"gas filter, filter for carrier gas GC, GC filters, filters hydrogen H2, filters nitrogen N2, filters helium He, detector filters, gas filters","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.instrument-solutions.com\/en\/consumables\/gc\/gc-filters","og_locale":"en_US","og_type":"article","og_title":"GC Filters - Instrument Solutions","og_description":"gas filter, filter for carrier gas GC, GC filters, filters hydrogen H2, filters nitrogen N2, filters helium He, detector filters, gas filters","og_url":"https:\/\/www.instrument-solutions.com\/en\/consumables\/gc\/gc-filters","og_site_name":"Instrument Solutions","article_modified_time":"2025-10-30T14:42:06+00:00","og_image":[{"width":337,"height":116,"url":"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/SGT-logo.jpg","type":"image\/jpeg"}],"twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.instrument-solutions.com\/en\/consumables\/gc\/gc-filters","url":"https:\/\/www.instrument-solutions.com\/en\/consumables\/gc\/gc-filters","name":"GC Filters - Instrument Solutions","isPartOf":{"@id":"https:\/\/www.instrument-solutions.com\/en#website"},"primaryImageOfPage":{"@id":"https:\/\/www.instrument-solutions.com\/en\/consumables\/gc\/gc-filters#primaryimage"},"image":{"@id":"https:\/\/www.instrument-solutions.com\/en\/consumables\/gc\/gc-filters#primaryimage"},"thumbnailUrl":"http:\/\/www.instrument-solutions.com\/wp-content\/uploads\/SGT-logo-300x103.jpg","datePublished":"2021-08-03T10:14:22+00:00","dateModified":"2025-10-30T14:42:06+00:00","description":"gas filter, filter for carrier gas GC, GC filters, filters hydrogen H2, filters nitrogen N2, filters helium He, detector filters, gas filters","breadcrumb":{"@id":"https:\/\/www.instrument-solutions.com\/en\/consumables\/gc\/gc-filters#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.instrument-solutions.com\/en\/consumables\/gc\/gc-filters"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.instrument-solutions.com\/en\/consumables\/gc\/gc-filters#primaryimage","url":"http:\/\/www.instrument-solutions.com\/wp-content\/uploads\/SGT-logo-300x103.jpg","contentUrl":"http:\/\/www.instrument-solutions.com\/wp-content\/uploads\/SGT-logo-300x103.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.instrument-solutions.com\/en\/consumables\/gc\/gc-filters#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.instrument-solutions.com\/en\/home"},{"@type":"ListItem","position":2,"name":"Consumables","item":"https:\/\/www.instrument-solutions.com\/en\/consumables"},{"@type":"ListItem","position":3,"name":"Consumables GC","item":"https:\/\/www.instrument-solutions.com\/en\/consumables\/gc"},{"@type":"ListItem","position":4,"name":"GC Filters"}]},{"@type":"WebSite","@id":"https:\/\/www.instrument-solutions.com\/en#website","url":"https:\/\/www.instrument-solutions.com\/en","name":"Instrument Solutions","description":"elementanalyse | chromatografie | elektronische sensing","publisher":{"@id":"https:\/\/www.instrument-solutions.com\/en#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.instrument-solutions.com\/en?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.instrument-solutions.com\/en#organization","name":"Instrument Solutions Benelux B.V.","url":"https:\/\/www.instrument-solutions.com\/en","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.instrument-solutions.com\/en#\/schema\/logo\/image\/","url":"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/logo-instrument-solutions-transparant.png","contentUrl":"https:\/\/www.instrument-solutions.com\/wp-content\/uploads\/logo-instrument-solutions-transparant.png","width":728,"height":325,"caption":"Instrument Solutions Benelux B.V."},"image":{"@id":"https:\/\/www.instrument-solutions.com\/en#\/schema\/logo\/image\/"}}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/www.instrument-solutions.com\/en\/wp-json\/wp\/v2\/pages\/13460","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.instrument-solutions.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.instrument-solutions.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.instrument-solutions.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.instrument-solutions.com\/en\/wp-json\/wp\/v2\/comments?post=13460"}],"version-history":[{"count":9,"href":"https:\/\/www.instrument-solutions.com\/en\/wp-json\/wp\/v2\/pages\/13460\/revisions"}],"predecessor-version":[{"id":47864,"href":"https:\/\/www.instrument-solutions.com\/en\/wp-json\/wp\/v2\/pages\/13460\/revisions\/47864"}],"up":[{"embeddable":true,"href":"https:\/\/www.instrument-solutions.com\/en\/wp-json\/wp\/v2\/pages\/13900"}],"wp:attachment":[{"href":"https:\/\/www.instrument-solutions.com\/en\/wp-json\/wp\/v2\/media?parent=13460"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}